| Simultaneous Determination of Copper,Manganese and Magnesium Contents in Natural Rubber Latex by Microwave Digestion and ICP-OES |
| Received:August 21, 2024 Revised:August 21, 2024 |
| DOI:10.12136/j.issn.1000-890X.2026.09.0707 |
| Key Words: natural rubber latex;microwave digestion;ICP-OES;element analysis |
| Author Name | Affiliation | E-mail | | XU Yongyuan | Natural Rubber and Coffee Product Quality Supervision and Inspection Station of Yunnan Province | 604359733@qq.com | | LI Quantao | Hubei University Yangtze River Delta Innovation Center | | | XIAO Yuxiu | Jiangxi Guangyuan Chemical Co., Ltd | | | ZHANG Ronghua | Yunnan Natural Rubber Industry Group Co., Ltd | | | LI Fengwei | Natural Rubber and Coffee Product Quality Supervision and Inspection Station of Yunnan Province | | | RUAN Linguang | Yunnan Natural Rubber Industry Group Co., Ltd | | | YANG Deming | Natural Rubber and Coffee Product Quality Supervision and Inspection Station of Yunnan Province | | | ZHU Yanjin* | Yunnan Natural Rubber Industry Group Co., Ltd | zhuyanjinok@126.com |
|
| Hits: 122 |
| Download times: 48 |
| Abstract: |
| By using microwave digestion and inductively coupled plasma optical emission spectrometry(ICP-OES),optimizing the conditions of microwave digestion system and digestion program parameters,and screening suitable element analysis spectral lines,the simultaneous and rapid determination of copper,manganese and magnesium contents in natural rubber latex was achieved.The results showed that,the mass concentrations of copper,manganese and magnesium standard solutions in this method had a good linear relationship with the intensities of characteristic spectral lines in the range of 0~10.00 mg·L-1,
the correlation factor was above 0.999 7.The relative standard deviations of the three elements were 1.68%~2.61%,the limits of detection were 0.013~0.035 mg·kg-1,and the recovery rates were 99.12%~102.83%,which could meet the relevant detection requirements. |
|
View Full Text
View/Add Comment Download reader |
| Close |