文章摘要
Improvement of Test Method for 45 µm Sieve Residue Weight of Precipitated Silica
Received:May 10, 2022  Revised:May 10, 2022
DOI:10.12136/j.issn.1000-890X.2024.05.0389
Key Words: precipitated silica;45 µm sieve residue;soaking;washing;test
Author NameAffiliationE-mail
xiongjinli china carbon black Institute 332951424@qq.com 
dengyi china carbon black Institute  
maoshanbing* 确成硅化学股份有限公司 maoshanbing@quechen.com 
Hits: 585
Download times: 525
Abstract:
      The testing method for 45 μm sieve residue weight of precipitated silica(5 g) was improved.The results showed that the sample was soaked in sodium hydroxide(NaOH) solutiona with volume fraction of 3% and stirred at low speed for 10 min,the sample had a shorter washing time and better washing effect,and the repeatability of 45 μm sieve residue weight test value was higher.After conducting four parallel tests on the micro bead shaped samples before and after soaking in NaOH solution,the reproducibility precision of 45 μm sieve residue weight test value met the requirements of national standard,so that soaking the sample could significantly shorten washing and save the water consumption.
View Full Text   View/Add Comment  Download reader
Close