文章摘要
Qualitative and Quantitative Analysis of Accelerator DPG in Vulcanizates by UPLC/Q-TOF MS
Received:September 21, 2018  Revised:September 21, 2018
DOI:10.12136/j.issn.1000-890X.2019.02.0151
Key Words: UPLC/Q-TOF MS;accelerator DPG;qualitative analysis;quantitative analysis
Author NameAffiliationE-mail
WEN Shao* Stone Laboratory Co. ,Ltd wens@stonelab.com.cn 
ZHANG Qingzhi Stone Laboratory Co. ,Ltd  
WU Aiqin Stone Laboratory Co. ,Ltd  
Hits: 1100
Download times: 535
Abstract:
      A qualitative and quantitative analysis of the accelerator DPG in vulcanizates was established by UPLC/Q-TOF MS,gradient elution with acetonitrile+water(volume fraction of methanoic acid was 0.000 3) as mobile phase was applied,and ESI source and positive ion mode were used for mass-spectrometry. The results showed that,the standard curve of accelerator DPG solution had good linearity with the real value in the range of mass concentration from 1 to 1 000 ng·mL-1R2 was 0.995,the detection limit was 0.01 ng·mL-1,and the recovery was 94.0%~100.5%.