Comparison of Lifting Performance of Two-stage Double-thread Shortamplitude Internal and External Cycloidal Screw Pumps |
Received:July 09, 2018 Revised:August 06, 2018 |
DOI:10.12136/j.issn.1000-890X.2019.09.0699 |
Key Words: short-amplitude external cycloid;short-amplitude internal cycloid;screw pump;lifting performance;critical contact stress |
Author Name | Affiliation | E-mail | DU Xiuhua | Northeast Petroleum University | 18045998544@163.com | JIA Sihan | Northeast Petroleum University | | HAN Daoquan* | Northeast Petroleum University | 18045998544@163.com | GUAN Ce | Northeast Petroleum University | |
|
Hits: 1129 |
Download times: 497 |
Abstract: |
Taking two-stage double-thread short-amplitude internal cycloidal screw pump as the
research object,the chamber pressure formation and lifting performance such as lifting pressure and
displacement were analyzed. The results showed that,compared with the double-thread short-amplitude
internal cycloidal screw pump,the lifting pressure and displacement of external cycloidal pump were reduced
by about 30%. Therefore,the external cycloidal screw pump was more suitable for applications in the shallow
wells with low production due to its low production and maintenance cost,while use of the internal cycloidal
screw pump in oil field could improve work efficiency and save time effectively. |
View Full Text
View/Add Comment Download reader |