Determination of Molecular Weight and Its Distribution of MPVQ by Gel Permeation Chromatography-Laser Light Scattering Method |
Received:March 24, 2018 Revised:March 24, 2018 |
DOI:10.12136/j.issn.1000-890X.2019.03.0230 |
Key Words: polymethulphenyl-vinyl silicone rubber;gel permeation chromatography-laster light scattering;molecular weight;molecular weight distribution |
Author Name | Affiliation | E-mail | TAN Limin* | The 42nd Institute of the Fourth Academy of CASC | 358957343@qq.com | LI Shenghua | The 42nd Institute of the Fourth Academy of CASC | | WANG Min | The 42nd Institute of the Fourth Academy of CASC | | ZHANG Yuanyuan | The 42nd Institute of the Fourth Academy of CASC | |
|
Hits: 1159 |
Download times: 887 |
Abstract: |
The molecular weight and its distribution of polymethylphenyl-vinyl silicone rubber(MPVQ)were determined by gel permeation chromatography(GPC)-laser light scattering(LLS) method. The testing conditions were as follows:solvent toluene,test temperature 25 ℃,flow speed 1 mL·min-1,sample solution mass concentration 4 mg·mL-1,injection volume 50 μL,and the dn/dc value of MPVQ was (0.058 9±0.002 5) mL·g-1.The relative standard deviations of the number average molecular weight and weight average molecular weight were 3.97% and 1.52%,respectively. This study showed that GPC-LLS method had high accuracy and precision. |