文章摘要
Optimization of Door Seal for DC600V Power Supply Device in Train
  
DOI:
Key Words: EPDM;seal;compression set
Author NameAffiliation
LI Gang Qingdao Sifang Rolling Stock Research Institute Co.,Ltd 
WANG Rong-guo Qingdao Sifang Rolling Stock Research Institute Co.,Ltd 
ZHANG Wei Hebei Huami Rubber Co.,Ltd 
Hits: 659
Download times: 344
Abstract:
      The causes of failure of the door seal for DC600V power supply device in train were analyzed,and then the seal was optimized by modification of the physical structure and improvement of the physical properties,such as increase of the density of seal and design of hollow structure.The results showed that the failure of seal was avoided after optimization,the quality of the product was improved,and the after-sales service cost was decreased.
View Full Text   View/Add Comment  Download reader